Description
Paper / aluminium / PVC / paper laminate, supplied in rolls and installed using standard wallcovering practice. It treats large surfaces: walls, ceilings, floors, partitions and doors.
Specifications
Rolls of 99 cm × 50 m, i.e. 49.5 m² · carton dimensions 114 × 18 × 18 cm · gross weight 9.53 kg · robust, tear-resistant laminate · installed with overlapping strips, no special tooling · white, printable in offset and flexography.
Applications
RF separation between two read zones: stockroom and sales floor, warehouse areas, adjoining premises · partitions, walls and ceilings.
Recommended adhesives
The adhesive must bond to the substrate and to the covering itself across the overlap area. Europe: Metylan Ovalit TM · Caparol CapaColl GK · Gewebe Kleber · Eukalin 1977 S.
RF performance
Attenuation of at least 40 dB over the 860–980 MHz range. 95 dB at 13.56 MHz in magnetic field.
Detailed UHF measurements, IEEE 299 method
| Frequency | Attenuation | Frequency | Attenuation |
|---|---|---|---|
| 860 MHz | 49 dB | 940 MHz | 49 dB |
| 870 MHz | 40 dB | 950 MHz | 52 dB |
| 880 MHz | 49 dB | 956 MHz | 53 dB |
| 890 MHz | 51 dB | 960 MHz | 47 dB |
| 900 MHz | 45 dB | 980 MHz | 61 dB |
| 910 MHz | 57 dB | ||
| 920 MHz | 47 dB | ||
| 930 MHz | 44 dB |
The IEEE 299 measurements shown above correspond to a campaign separate from the additional attenuation tests carried out by the Emitech laboratory.
Reaction to fire
France / Europe M1 classification to NF P 92-501 and NF P 92-507. Efectis classification report EFR-25-004130, rev. 1.
Australia and New Zealand Tested to AS ISO 9705:2003 R2016 and reported in accordance with AS 5637.1:2015. Group Number 1 · SMOGRARC 0.88. Tested configuration: ISO 3 bonded with ACM TEXRECO N, with a minimum 20 mm overlap at each joint. Ignis Labs report IGNL-100310-06R I01R00, issued 12 August 2026. Test sponsored by MerchSecure Solutions Pty Ltd.
Video
The video is loaded from YouTube only when you press play.